Rail Foot Profiles and Tie Bar Insulation

Electrical track insulation for stray current protection and durable infrastructure

Rail foot profiles and tie bar insulations electrically separate the rail from the structure and protect the track installation against corrosion. The track insulation components provide stray current protection for slab tracks and ensure an electrically separated rail support.

Product Features

  • Prevent corrosion in track installations
  • Reliable rail insulation to standard
  • Defined elastic rail support
  • Long-lasting gauge retention insulation for tramway
  • Easy installation without post-processing

Why insulation in track construction is necessary

Electrically operated railway systems carry return currents via the rail. Without suitable rail fastening insulation, leakage currents enter the concrete and reinforcement. The consequences are typical damage patterns:

  • Cracks in the concrete
  • Corrosion of components
  • Interference with signalling systems

Therefore, the question frequently arises during planning as to how track installations can be permanently electrically insulated. The solution is systematic rail insulation including the rail foot and the tie bar.

 

Rail foot insulation for different construction methods

Depending on the superstructure, the rail foot profile fulfils different tasks. In continuous elastic support, the profile controls the deflection. In sleeper support, it additionally provides electrical separation. The rail foot insulation ensures a defined bearing and prevents electrical leakage into the subgrade (e.g. concrete track slab).

 

Tie bar insulation in track construction

Tie bars transfer forces between the rails. Without an insulated tie bar, a direct current path is created. The tie bar insulation electrically separates this path and simultaneously stabilises the gauge retention. This ensures that the tramway gauge insulation remains permanently effective.

 

Operating principle of track insulation

The elastic components form a continuous insulation layer along the rail. The rail insulation prevents potential differences between rail and structure. This reduces electrochemical processes and extends the service life of the infrastructure. Stray current protection is thereby permanently ensured.

 

Material properties

The components are made from tested elastomer materials with defined mechanical properties.

  • Weatherproof
  • Temperature resistant
  • Durable
  • Economical
  • Standards-tested in accordance with DIN 45673-8
  • Electrically insulating in accordance with DIN 50122-2

Installation is self-clamping and without additional fastening.

 

Typical areas of application

  • Slab track systems
  • Sleeper track
  • Tramway and urban rail
  • Depots
  • Tunnels and bridges

Result in operation

  • Permanently electrically separated rail
  • Reduced corrosion
  • Stable gauge retention
  • Low maintenance costs

Technical support is provided on a project basis by HET Elastomertechnik.

Foot Profile Type Eco

Property

 

Value

Density

 

approx. 1.1 g/cm³

Tensile strength

 

2.32 to 2.63 N/mm²

Elongation at break

 

77 to 79 %

Shore Hardness A

 

70 ± 7

Specific electrical resistance

 

≥ 1,500 MΩm

 

Foot Profile Type VFP

Property

Value

Shore Hardness A

62 ± 5

Tensile strength

> 10 N/mm²

Elongation at break

> 380 %

Tear resistance

≥ 8 N/mm

Specific volume resistance

> 1 × 10⁹ Ω

 

Tie Bar Insulation TBE 70/10

Property

Value

Shore Hardness A

62 ± 5

Tensile strength

> 10 N/mm²

Elongation at break

> 380 %

Compression set (72 h RT)

≤ 30 %

Specific volume resistance

> 1 × 10⁹ Ω

Which solution fits your application?

Our experts will advise you on products, applications and find the optimal elastomer solution for your area of use.

Get advice now