V Fix
PU sealant compound for direct fastening of rails on concrete track slabs
V Fix is a high-strength PU sealant compound for the permanent fastening of rails on concrete. The V Fix PU sealant compound forms a load-bearing bed beneath rail fastening systems and enables a precise, low-maintenance slab track without ballasted superstructure.
Product Features
- Secure load transfer in the slab track fastening system
- Permanent electrical insulation of the rail
- Low maintenance through stable track geometry
- Suitable for bridges, tunnels and depot facilities
- Reduced construction height compared to ballasted track
Permanently solving rail fastening directly on concrete
Modern infrastructure demands compact construction methods and predictable service life. In direct fastening, the grout assumes the central structural function of the system. The V Fix grouting compound acts as a Rail Fastening Grout between the rail and the concrete track slab. Wheel loads are transferred over an area rather than introduced at points. This keeps the track geometry stable and the fastening permanently functional.
Application in slab track systems
In rail grouting directly on concrete, the rail is fastened via baseplates. The gap is filled with epoxy resin mortar and forms a load-bearing support. The rail support point grout fulfils several tasks:
- Uniform force transfer into the track slab
- Limitation of dynamic deflection
- Electrical insulation against stray current
- Precise height adjustment of the track geometry
- Compact construction without ballast
The dynamic deflection of the rail foot remains in the range of approximately 0.5 to 1.0 mm, corresponding to the behaviour of an elastically supported track.
Fastening with and without anchor bolts
Direct fastening with anchor bolts
In conventional fastening, baseplates are fixed with anchors in the concrete.
The undergrouting distributes the forces evenly into the subgrade.
Direct fastening without anchor bolts
Where drilling is structurally not permissible, the baseplate can be bonded directly.
The baseplate grout simultaneously provides connection and load distribution.
This construction method is particularly suitable for structures and waterproofing areas.
Operating principle of the undergrouting
The grout for rail fastening systems prevents localised stress peaks in the concrete surface. The high adhesion to steel and concrete is maintained even after frost-thaw cycles and load cycles. Additionally, the electrical resistance provides permanent insulation of the rail.
This reduces corrosion in the substructure.
Technical properties in operation
The baseplate undergrouting combines load-bearing capacity with controlled elasticity.
- High compressive strength for load transfer
- Low creep deformation
- Permanent adhesion without primer
- Chemically resistant
- Stray current insulating
- Defined bearing stiffness
Typical grouting thicknesses range between 15 and 65 mm depending on the application.
Typical areas of application
Ballastless rail fastening is used for:
- Rail fastening on bridges
- Rail fastening in tunnels
- Machine foundation rail grouting
- Traverser track fastening
- Tramway slab track
- Depot installations
- Repair of fastening points
Benefits for planning and operation
A stable rail support point reduces maintenance effort and extends the service life of the route.
- Constant track geometry
- Low maintenance
- Electrically insulated rail
- Predictable service life
Technical project support is available on request from HET Elastomertechnik.
FIX 50 D
Material properties at 23 °C
|
Property |
Standard |
Value |
|
Density |
ISO 2811-1 |
1.33 ±0.05 |
|
Hardness Shore D |
ISO 868 |
50 ±5 |
|
Hardness Shore D at 60 °C |
ISO 868 |
approx. 25 |
|
Elongation at break |
EN 527-2 |
≥ 30 % |
|
Compression modulus 10 % |
UNE EN ISO 604 |
88 MPa |
|
Adhesion to concrete |
EN 1542 |
≥ 2 MPa |
|
Adhesion to steel |
EN 1542 |
≥ 4 MPa |
|
Dynamic deformation rail foot |
EN 13481-5 |
0.5 – 1.0 mm |
|
Electrical insulation under 500 V |
1340-4-1 CET 1995 |
> 100 GΩ |
|
Temperature resistance |
– |
−20 °C to +60 °C |
|
Load-bearing at 23 °C |
– |
after 48 hours |
Supplementary properties
- Good adhesion to concrete and metal
- UV and hydrolysis resistant
- Stray current insulating
- Good chemical resistance
- Traffic release after 48 hours
Which solution fits your application?
Our experts will advise you on products, applications and find the optimal elastomer solution for your area of use.
Get advice now